Protection Grade

protction qrade of load cell
REF:Cateqory of national standard of crust protection on qrade
Equivalent:IEC529
IP-6-:dust proof
Grade Cutline testing me thod Protecion grade
IP6 5

spattering water proof

enclosure is spayed from all practicadle directions with a stream of water atl 12.5L/min from a 6.3mm nozzle from a distance of 2.5 to

3m.Test time=1min/m of enclosure surface area to be sprayed,3min iminim um.

Uncovered side of strain gages

should be sealed with glue.G en eric

lo ad cells can meet.

IP6 6

spattering water proof

enclosure is spayed from all practicadle directions with a stream of water at 100L/min from a 12.5m m nozzle from a distance of

2.5to 3m.Test time=1min/m of edclosure surface area to be sprayed,3min minimum.

these load cells can meet whose

cover board is sealed with glue

adn the interior part is infused

with glue.

IP6 7 Subm erg ed

Enclusure is immersed in water in its service position for 30min.Lowest point of enclosure less than 850mm tall=1000mm below surface of water.Highest point of enclosure more than 850mm tall=150mm below surface of water

these load cells can meet whose

cover board (or rippled pipe)is sealed with glue adn the interior

part is infused with glue.

IP6 8 Dived

Test condition are subject to egreem ent etween manufacturer and user,but shall be tlest as severe as those for ip67.