Load Cell and Weighing Scale
   中文版
   Contact
Welcome to Benui Electric Company
Benui Electric > Load cell > S type load cell > TSC S type load cell

TSC S type load cell

Model: TSC
Description:
Capacities:(Emax)

0.5,1,2,3,5,7.5,10,20t
Rated output:
2.0mV/V
Digital:1,000,000d
Accuracy: C3 OIML R60
Material of elastomer: Alloy steel or stainless steel

Details Description

Execution standard:
GB/T 7551-1997 Certificate
(eqv OIML R60)
Combined error: 0.015%

Sealed to IEC 529:
Protection grade: IP67 or IP68.
Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.

Dimensions

(In mm. 1mm = 0.03937 inches)

TSC S type load cellTSC S type load cell

CAP./SIZE(kg) H B W M
0.5,1,2,3t 86 64 28 M16
5t 106 80 36 M24*2
7.5,10t 178 130 51 M30*2
15,20t 190 160 60 M39*2

 

Circuit Diagram:

Electrical Termination
4 Core cable standard lengths:
1~3t: 3m, 5~10t: 6m, 20t: 10m
Diameter: Φ6
Connection:
Refer to the following drawing:

TSA S type load cell

Notice: Do not change the length of cable, or lese, it will effect the sensitivity of load cell.

 

Specification

Item\ Parameter C3 Unit
Rated load (Emax): 0.5,1,2,3,5,7.5,10,20 t
Maximal numbers of load cell verification Intervals (Nlc): 3000 d
Minimum load cell verification intervals Intervals ( Vmin): 0.01 % of rated load
Rated output (Cn): 2.0±0.1% mV/V
Combined error: 0.015 -% of rated output
Temperature effect on sensitivity(Tkc): 0.0012 =% of rated output/
Temperature effect on zero balance(Tk0): 0.0008 -% of rated output
Zero balance: 1.0 -% of rated output
Input resistance(Rlc): 385±5 Ω(Ohms)
Output resistance(Ro): 351±2 Ω(Ohms)
Insulation resistance: ≥5000 MΩ (Mega-Ohms)
Safe overload: 150 % of rated capability
Ultimate overload: 300 % of rated capability
Operating temperature range: -20~+70/-20~+160 ℃/ °F
Recommend excitation: 8~15 V( DC or AC)
Maximum excitation: 18 V( DC or AC)
Material of elastomer: Alloy steel / Stainless steel
Protection class: IP67/IP68

The data for deviation of synthesis error,TK0,TKc are typicl values. The sum of these
data meets the requirements according to OIML R60