RNT-M Torsional ring module

Model: RNT-M
Description:
Capacities:(Emax)
1,2.2,4.7,10,22,33,47t
Rated output:
2.0mV/V
Digital:1,000,000d
Accuracy: C3 OIML R60
Material of elastomer: Alloy steel or stainless steel

Details Description

Execution standard:
GB/T 7551-1997 Certificate
(eqv OIML R60)
Combined error: 0.015%

Sealed to IEC 529:
Protection grade: IP67 or IP68.
Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.

 

Dimensions

(In mm. 1mm = 0.03937 inches)

RNT-M Torsional ring module RNT-M Torsional ring module

CAP./SIZE A B H H1 Φ
1~4.7t 94 120 114.4 18 13
10~22t 94 120 137.8 18 13
33t 105 130 181.1 22 18
47t 124 160 228.7 22 18

 

Circuit Diagram:

Electrical Termination
4 Core cable standard lengths:
<=15t: 5.0 m, 22~47t: 13m
Diameter: Φ6
Connection: Refer to the following drawing:

 

Notice: Do not change the length of cable, or lese, it will effect the sensitivity of load cell.

 

Specification

Item\ Parameter C3 Unit
Rated load (Emax): 1,2.2,4.7,10,22,33,47 t
Maximal numbers of load cell verification Intervals (Nlc): 3000 d
Minimum load cell verification intervals Intervals ( Vmin): 0.01 % of rated load
Rated output (Cn): 2.0±0.1% mV/V
Combined error: 0.015 -% of rated output
Temperature effect on sensitivity(Tkc): 0.0012 =% of rated output/
Temperature effect on zero balance(Tk0): 0.0008 -% of rated output
Zero balance: 1.0 -% of rated output
Input resistance(Rlc): 775±5/>=33t:1550± 10 Ω(Ohms)
Output resistance(Ro): 702±2/>=33t:1402± 2 Ω(Ohms)
Insulation resistance: ≥5000 MΩ (Mega-Ohms)
Safe overload: 150 % of rated capability
Ultimate overload: 300 % of rated capability
Operating temperature range: -20~+70/-20~+160 ℃/ °F
Recommend excitation: 8~24 V( DC or AC)
Maximum excitation: 48 V( DC or AC)
Material of elastomer: Alloy steel / Stainless steel
Protection class: IP67/IP68

The data for deviation of synthesis error,TK0,TKc are typicl values. The sum of these
data meets the requirements according to OIML R60