BTY-MF Self-restoring rocker-pin module

Model: BTY-MF

Description:

Capacities:(Emax)
10,20,30,40 t.
Output:
2.0mV/V
Digital:1,000,000d.

Accuracy: C3 OIML R60.
Material of elastomer: Alloy steel or stainless steel.

Details Description

Execution standard:
GB/T 7551-2008 Certificate
(eqv OIML R60)
Combined error: 0.015%

Sealed to IEC 529:
Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.

Dimensions

(In mm. 1mm = 0.03937 inches)

BTY-MF Self-restoring rocker-pin module BTY-MF Self-restoring rocker-pin module

 

Circuit Diagram:

Electrical Termination
4 Core cable standard lengths:12.0 m.
Diameter:Φ6
Connection:
Refer to the following drawing..

BTY-MF Self-restoring rocker-pin module

Notice:Do not change the length of cable, or lese, it will effect the sensitivity of load cell.

 

Specification


Item\ Parameter C3 Unit
Rated load (Emax): 10,20,30,40 t
Maximal numbers of load cell verification
Intervals (Nlc):
3000 d
Minimum load cell verification intervals

Intervals ( Vmin):
0.01 % of rated load
Rated output (Cn): 2.0±0.1% mV/V
Combined error: 0.015 -% of rated output
Temperature effect on sensitivity(Tkc): 0.0012 =% of rated output/
Temperature effect on zero balance(Tk0): 0.0008 -% of rated output
Zero balance: 1.0 -% of rated output
Input resistance(Rlc): 775±5 Ω(Ohms)
Output resistance(Ro): 702±2 Ω(Ohms)
Insulation resistance: ≥5000 MΩ (Mega-Ohms)
Safe overload: 150 % of rated capability
Ultimate overload: 300 % of rated capability
Operating temperature range: -20~+70/-20~+160 ℃/ °F
Recommend excitation: 8~15 V( DC or AC)
Maximum excitation: 24 V( DC or AC)
Material of elastomer:

Alloy steel / Stainless steel

Protection class:

IP67/IP68

The data for deviation of synthesis error,TK0,TKc are typicl values. The sum of these
data meets the requirements according to OIML R60