Load Cell and Weighing Scale
   中文版
   Contact
Welcome to Benui Electric Company

BCP Column load cell

Model: BCP
Description:
Capacities:(Emax)
20,30,50,100,200,300 klbs.
Output:
2.0mV/V
Digital:1,000,000d.

Accuracy: C3 OIML R60.

Material of elastomer: Alloy steel or stainless steel.

  Details >>
Details Description

Execution standard:
GB/T 7551-2008 Certificate
(eqv OIML R60)
Combined error : 0.027%

Sealed to IEC 529:
Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.

Dimensions

(In mm. 1mm = 0.03937 inches)

BCP Column load cell BCP Column load cell

CAP./SIZE A B C D E F H K L
20~50 klbs   190.5 114.3 57.1 31.8 12.7 19.1 63.5 60.3 3/8-24
100klbs 231.8 152.4 79.4 44.5 15.9 27.0 64.3 101.6 1/2-20
200klbs 295.3 203.2 114.3 63.5 15.9 27.0 89.7 139.7 5/8-18
300klbs 355.8 252 127 76.2 19.1 33.3 109.5 139.7 3/4-16

 

Circuit Diagram:

Electrical Termination
4 Core cable standard lengths:
<=50klbs: 3.0 m, >=100klbs: 10m.
Diameter:Φ6
Connection:
Refer to the following drawing:

BCP Column load cell

Notice:Do not change the length of cable, or lese, it will effect the sensitivity of load cell.

 

Specification


Item\ Parameter C3 Unit
Rated load (Emax):

20,30,50,100,200,300

klbs
Maximal numbers of load cell verification
Intervals (Nlc):
3000 d
Minimum load cell verification intervals

Intervals ( Vmin):
0.01 % of rated load
Rated output (Cn): 2.0±0.1% mV/V
Combined error: 0.015 -% of rated output
Temperature effect on sensitivity(Tkc): 0.0012 =% of rated output/
Temperature effect on zero balance(Tk0): 0.0008 -% of rated output
Zero balance: 1.0 -% of rated output
Input resistance(Rlc): 775±5 Ω(Ohms)
Output resistance(Ro): 702±2 Ω(Ohms)
Insulation resistance: ≥5000 MΩ (Mega-Ohms)
Safe overload: 150 % of rated capability
Ultimate overload: 300 % of rated capability
Operating temperature range: -20~+70/-20~+160 ℃/ °F
Recommend excitation: 8~15 V( DC or AC)
Maximum excitation: 24 V( DC or AC)
Material of elastomer:

Alloy steel / Stainless steel

Protection class:

IP67/IP68

The data for deviation of synthesis error,TK0,TKc are typicl values. The sum of these
data meets the requirements according to OIML R60