Load Cell and Weighing Scale
   中文版
   Contact
Welcome to Benui Electric Company
Benui Electric > Load cell > Wireless load cell > APLC Axle pad load cell

APLC Axle pad load cell

Model: APLC
Description:
Capacities:(Emax)
1,2,3,5,7.5,10 t.

Rated output:
2.0mV/V
Digital:1,000,000d.

Accuracy:C2 OIML R60
Material of elastomer: Alloy steel or stainless steel

  Details >>
Details Description

Execution standard:
GB/T 7551-2008 Certificate
(eqv OIML R60)
Combined error: 0.027%

Sealed to IEC 529:
Protection grade: IP67 or IP68. Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1 m head of water.

 

Dimensions

(In mm. 1mm = 0.03937 inches)

APLC Axle pad load cell

APLC Axle pad load cell

 

Circuit Diagram:

Electrical Termination
4 Core cable standard lengths:1m
Diameter:Φ5
Connection: Refer to the following drawing:

APLC Axle pad load cell

Item\ Parameter C3 Unit
Rated load (Emax):

1,2,3,5,10

t
Maximal numbers of load cell verification
Intervals (Nlc):
2000 d
Minimum load cell verification intervals

Intervals ( Vmin):
0.02 % of rated load
Rated output (Cn): 2.0±0.1% mV/V
Combined error: 0.027 ±% of rated output
Temperature effect on sensitivity(Tkc): 0.0024 ±% of rated output/℃
Temperature effect on zero balance(Tk0): 0.002 ±% of rated output/℃
Zero balance: 1.0 ±% of rated output
Input resistance(Rlc): 775±5 Ω(Ohms)
Output resistance(Ro): 702±2 Ω(Ohms)
Insulation resistance: ≥5000 MΩ (Mega-Ohms)
Safe overload: 150 % of rated capability
Ultimate overload: 300 % of rated capability
Operating temperature range:

-20~+70/-20~+160

℃/ °F
Recommend excitation: 8~15 V( DC or AC)
Maximum excitation: 24 V( DC or AC)
Material of elastomer:

Alloy steel / Stainless steel

Protection class:

IP67/IP68

The data for deviation of synthesis error,TK0,TKc are typicl values. The sum of these
data meets the requirements according to OIML R60